2.1 Input Voltage
Input voltage range:85~264Vac
Rated Voltage:100-240Vac
2.2 Input Frequency
Rated Frequency Range:50/60Hz.
Working Frequency Range:47-63Hz.
2.3 Input AC Current
2A Max / 115VAC
1.5A Max / 230VAC.
Model |
68-5-12 |
68-5-24 |
68-5-36 |
68-12-24 |
68-12-36 |
|
Output 输出 |
DC Voltage
|
CH1:5V CH2:12V |
CH1:5V CH2:24V |
CH1:5V CH2:36V |
CH1:12V CH2:24V |
CH1:12V CH2:36V |
Rated Current
|
CH1:4A CH2:4A |
CH1:4A CH2:2A |
CH1:4A CH2:1.33A |
CH1:1.67A CH2:2A |
CH1:1.67A CH2:1.33A |
|
current range
|
CH1:0-4A CH2:0-4A |
CH1:0-4A CH2:0-2A |
CH1:0-4A CH2:0-1.33A |
CH1:0-1.67A CH:0-2:2A |
CH1:0-1.67A CH2:0-1.33A |
|
rated power
|
68W |
68W |
68W |
68W |
68W |
|
Ripple&Noise
|
CH1:80mV CH2:100mV |
CH1:80mV CH2:150mV |
CH1:80mV CH2:2000mV |
CH1:80mV CH2:150mV |
CH1:100mV CH2:200mV |
|
Voltage
|
CH1:4.75~5.5V |
CH1:4.75~5.5V |
CH1:4.75~5.5V |
CH1:4.75~5.5V |
CH1:4.75~5.5V |
|
Voltage accuracy
|
CH1:±2.0% CH2:±4%,-8% |
CH1:±2.0% CH2:±4%,-8% |
CH1:±2.0% CH2:±4%,-8% |
CH1:±2.0% CH2:±4%,-8% |
CH1:±2.0% CH2:±4%,-8% |
|
line regulation
|
CH1:±0.5% CH2:±1.5% |
CH1:±0.5% CH2:±2% |
CH1:±0.5% CH2:±2.5% |
CH1:±0.5% CH2:±2% |
CH1:±0.5% CH2:±2.5% |
|
Load Regulation
|
CH1:±0.5% CH2:±3% |
CH1:±0.5% CH2:±6% |
CH1:±0.5% CH2:±10% |
CH1:±0.5% CH2:±6% |
CH1:±0.5% CH2:±10% |
4.1 Over Current Protection
110-140% of rated output current
4.2 Short Circuit Protection
The power supply shall be turned off when operating any output in an overload condition, or when operating any output in a short circuit condition. The power supply shall be safe to restart when the fault condition is removed.(output shorted mode input average power 5W max. )
4.3 Over Temperature Protection
115Vac 60Hz & 230Vac 50Hz Input full load under the condition of continuous work for 4 hours, not deformation, fire, smoke, combustion, explosion and other danger happening.
4.4 Output over voltage protection
Model |
68-5-12 |
68-5-24 |
68-5-36 |
68-12-24 |
68-12-36 |
Output over voltage protection
|
5.75~6.75V |
5.75~6.75V |
5.75~6.75V |
5.75~6.75V |
5.75~6.75V |
Protected mode: Hiccup mode, which can be automatically recovered after removing abnormal load conditions
|
4.5 Temperature Rise of External Surface
The temperature rise of housing is a maximum of 65℃ at the input voltage of 100-120Vac&220-240Vac with Rated Load, under the temperature of 25℃.
Email cannot be empty
Password cannot be empty
Email format error
Email cannot be empty
Email already exists
6-20 characters(letters plus numbers only)
The password is inconsistent
Email format error
Email cannot be empty
Email does not exist
6-20 characters(letters plus numbers only)
The password is inconsistent