2.1 Input Voltage
Input voltage range:85~264Vac
Rated Voltage:100-240Vac
2.2 Input Frequency
Rated Frequency Range:50/60Hz.
Working Frequency Range:47-63Hz.
2.3 Input AC Current
4A Max / 115VAC
2A Max / 230VAC.
Model |
350-12 |
350-24 |
350-36 |
350-48 |
|
Output
|
DC Voltage
|
12V |
24V |
36V |
48V |
Rated Current
|
29.2A |
14.6A |
9.7A |
7.3A |
|
current range
|
0~29.2A |
0~14.6A |
0~9.7A |
0~7.3A |
|
rated power
|
350.4W |
350.4W |
349.2W |
350.4W |
|
Ripple&Noise
|
150mVp-p |
240mVp-p |
360mVp-p |
480mVp-p |
|
Voltage Adjustment Range
|
10.2~13.8V |
21.6~28.8V |
32.4~39.6V |
43.2~52.8V |
|
Voltage accuracy
|
±1.0% |
±1.0% |
±1.0% |
±1.0% |
|
line regulation
|
±0.5% |
±0.5% |
±0.5% |
±0.5% |
|
Load Regulation
|
±0.5% |
±0.5% |
±0.5% |
±0.5% |
4.1 Over Current Protection
120-150% of rated output current
4.2 Short Circuit Protection
The power supply shall be turned off when operating any output in an overload condition, or when operating any output in a short circuit condition. The power supply shall be safe to restart when the fault condition is removed.(output shorted mode input average power 5W max. )
4.3 Over Temperature Protection
115Vac 60Hz & 230Vac 50Hz Input full load under the condition of continuous work for 4 hours, no deformation, fire, smoke, combustion, explosion and other danger happening.
Model |
350-12 |
350-24 |
350-36 |
350-48 |
Over Temperature protection |
The power supply will be turned off. The power supply shall be safe to restart when the temperature drops. |
4.4 Output Over Voltage Protection
Model |
350-12 |
350-24 |
350-36 |
350-48 |
Output over voltage protection |
13.8~16.2V |
28.8~33.6V |
41.4~48.6V |
55.2~64.8V |
|
The power supply will be turned off. The power supply shall be safe to restart when the fault condition is removed. |
4.5 Temperature Rise of External Surface
The temperature rise of housing is a maximum of 65℃ at the input voltage of 100-120Vac&220-240Vac with Rated Load and Environment Requirements, under the temperature of 25℃。
Email cannot be empty
Password cannot be empty
Email format error
Email cannot be empty
Email already exists
6-20 characters(letters plus numbers only)
The password is inconsistent
Email format error
Email cannot be empty
Email does not exist
6-20 characters(letters plus numbers only)
The password is inconsistent